Pull out the fiberglass and install r 20 dense pack cellulose by national fiber for the rafter bays at the cathedral and r 40 for the attic floor.
16 inch dense pack cellulose roof.
For instance a 2 1 2 inch gap between the inner and outer frames creates a total 10 inch cavity that when filled with dense pack cellulose achieves a nominal insulating value of around r 31.
Do not install cellulose below active roof leaks.
Address wet basements or crawlspaces before insulating your roof.
There are continuous soffit vents.
According to one source loose fill cellulose has an r value of r 3 8 per inch while dense packed cellulose at 3 5 pounds per cubic foot has a slightly lower r value of r 3 65 per inch.
I am thinking about this and my assembly would look like.
A properly applied dense packing of cellulose provides excellent r value to the home at 3 5 and 4 0 per inch dense packing cellulose helps stop air flow and improves home comfort.
What is the r value of nu wool premium cellulose insulation.
Consumer protection safety commission 16 cfr parts 1209 and 1404.
What requirements are there for thermal insulation.
Flat roof being dense packed the roof is opened up and cellulose is being blown into the roof cavity dense packing it.
This is a technique that dense packs 3 7 lb of cellulose per cubic feet into existing wall and roof cavities.
Because the space between the inner and outer walls creates a thermal break that reduces heat loss through the framing members the actual r value will.
Greenfiber the fiberized cellulose introduced in 1990 has about the same r value per inch.
The guy in the middle is jim fitzerald the absolute best guy in the world and he could not make it.
And while the low density fiberglass insulation used in attics rates a much lower r 2 0 per inch there is typically very little space restriction in attics.
Pull out any existing fiberglass or make sure that you can dense pack the cellulose to the outside.
Shingles roof felt ice guard osb taped seams dense pack cellulose intello drywall paint.
The house is a cape with a shed dormer roof with front pitch 6 12 and shed pitch 2 1 2 12.
Fiberglass batts and cellulose used in walls earn similar conductive ratings between r 3 and r 4 per inch depending on density.
Flat roof there are a gazillion of these roofs that are uninsulated and need to be addressed.
The 475 blog has a new post about unvented dense pack cellulose cathedral ceiling flat roof systems using intello membrane on the inside to allow the assembly to dry to the inside.
However according to bohdan boyko a technical rep from u s.